Lutron QS Energi Savr Node Phase-Adaptive (220-240V)
LUTRON QSNE-4A-D
The Lutron QS Energi Savr Node (ESN) is modular din rail mounted 4 zone lighting controller suitable for dimming both leading and trailing edge. The node can be used as a standalone unit or configured to work with the Grafikeye QS. Designed to be mounted remotely in a din rail enclose the ESN requires Lutron seeTouch wall stations. These keypads can be programmed to with up to 16 scenes and can be assigned to more than one Energi Savr Node. The keypads available in a range of buttons configurations and finishes to suit any interior.
The Energi Savr Node can be set to respond to zone toggle or occupancy sensor commands initiated by the QSE-IO in scene toggle mode or occupancy sensor mode.
Please note the QSNE-4A-D will need programming using the Energi Savr Node Programming Interface (QSE-CI-AP-D) which is sold separately.
Specifications
• No minimum load requirement
• Automatically selects leading-edge or trailing-edge dimming or can also be manually configured for a specific load type.
• For applications requiring 0–10 V- control, use Ten Volt Interface (GRX-TVI)
Power
• 220–240 V~ 50/60 Hz
• 10 A maximum total input current
• Lightning strike protection meets ANSI/IEEE standard 62.31-1980. Can withstand voltage surges of up to 6 000 V and current surges of up to 3 000 A.
• 24 V- 132 mA, 4 PDUs supplied Regulatory Approvals
• IEC/EN 60669-2-1
• CE marked
- Description
Description
LUTRON QSNE-4A-D
The Lutron QS Energi Savr Node (ESN) is modular din rail mounted 4 zone lighting controller suitable for dimming both leading and trailing edge. The node can be used as a standalone unit or configured to work with the Grafikeye QS. Designed to be mounted remotely in a din rail enclose the ESN requires Lutron seeTouch wall stations. These keypads can be programmed to with up to 16 scenes and can be assigned to more than one Energi Savr Node. The keypads available in a range of buttons configurations and finishes to suit any interior.
The Energi Savr Node can be set to respond to zone toggle or occupancy sensor commands initiated by the QSE-IO in scene toggle mode or occupancy sensor mode.
Please note the QSNE-4A-D will need programming using the Energi Savr Node Programming Interface (QSE-CI-AP-D) which is sold separately.
Specifications
• No minimum load requirement
• Automatically selects leading-edge or trailing-edge dimming or can also be manually configured for a specific load type.
• For applications requiring 0–10 V- control, use Ten Volt Interface (GRX-TVI)
Power
• 220–240 V~ 50/60 Hz
• 10 A maximum total input current
• Lightning strike protection meets ANSI/IEEE standard 62.31-1980. Can withstand voltage surges of up to 6 000 V and current surges of up to 3 000 A.
• 24 V- 132 mA, 4 PDUs supplied Regulatory Approvals
• IEC/EN 60669-2-1
• CE marked